Printed in U.S.A. 10/10 318181-000
SERVICE HANDBOOK FOR
STANDARD RESIDENTIAL
HIGH EFFICIENCY ATMOSPHERIC VENT
(FVIR) GAS WATER HEATERS
MODELS:
GAHH 40 100,
GP 6 40YPC T 100,
PCG6240T403NOV 100,
PCG2J4040T3NOV 100,
12 40GPC T 100,
PCG2J4040T3NOV 100,
GAHH 50 100,
GP 6 50YPC T 100,
PCG250T403NOV 100,
PCG2J5040T3NOV 100,
12 50GPC T 100,
PCG2J5040T3NOV 100
http://waterheatertimer.org/Review-AO-Smith-Effex-water-heater.html
Przeglądanie stron 0
1 2 3 4 5 6 ... 55 56

Podsumowanie treści

Strona 1 - (FVIR) GAS WATER HEATERS

1Printed in U.S.A. 10/10 318181-000SERVICE HANDBOOK FOR STANDARD RESIDENTIALHIGH EFFICIENCY ATMOSP

Strona 2

10• The connector must be firmly attached and sealed to prevent it from falling out.• To aid in removing the connector, a thimble or slip joint may

Strona 3 - SERVICE HANDBOOK

11KNOW THE WATER HEATER’S COMPONENT PARTSFigure 11.Electronic Control Display (Upper Control)The Electronic Control Display panel used on this water h

Strona 4 - Fire or Explosion Harzard

12KNOW THE WATER HEATER’S COMPONENT PARTSBurner/Manifold Door AssemblyThe burner/manifold door assembly consists of several components such as: main b

Strona 5 - TABLE OF CONTENTS

13KNOW THE WATER HEATER’S COMPONENT PARTSFlammable Vapor Cut Off Switch (FV Sensor)The water heater is equipped with a FV sensor, for detecting the pr

Strona 6 - Figure 1

14WATER HEATER OPERATIONThe figure below shows the water heater’s sequence of operation when a call for heat is initiated. The gas control valve/therm

Strona 7 - Carbon Monoxide Warning

15FILLING, DRAINING AND FLUSHING THE WATER HEATER TANKIt is recommended that the tank be drained and flushed every 6 months to remove sediment which m

Strona 8

16LIGHTING INSTRUCTIONSRead and understand these directions thoroughly before attempting to operate the water heater. Make sure the view port is not m

Strona 9

17ADJUSTING THE TEMPERATURE ON THEELECTRONIC CONTROL DISPLAYAdjusting the Temperature Set Point - The thermostat of this water heater has been factory

Strona 10

18USING THE ELECTRONIC CONTROL DISPLAYHow to select or change the temperature scale from Fahrenheit (°F) to Celsius (°C).Figure 22. 1. The temperatur

Strona 11 - (Upper Control)

19USING THE ELECTRONIC CONTROL DISPLAYReviewing Fault Codes: 1. Press the red up arrow button one time. 2. The display will show either E0 or E1. 3.

Strona 12 - Pressure

2ALL TECHNICAL AND WARRANTY QUESTIONSSHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED.IF YOU ARE UNSUCCESSFUL, CONTACT

Strona 13 - FV Sensor

20 Please check guidelines below. For your safety, water heater service should be performed only by a qualied service person.Read the GENERAL SAFETY

Strona 14 - SEQUENCE OF OPERATION

21 6. “P-SW”, “OPEN”, and “CLEAN SCREEN” Flashing The air pressure switch contacts remain open longer than 11 seconds after the combustion fan is en

Strona 15

22CONTROL DISPLAY TROUBLESHOOTING 11. “FV-SENSE” and “OPEN” Flashing Flammable Vapor Sensor is open 1. Check all wiring to the ammable vapor sens

Strona 16 - LIGHTING INSTRUCTIONS

23Please Note:The control continually monitorsinternal circuits and external sensors.Error codes noted above, and those forself-diagnostic faults can

Strona 17 - ELECTRONIC CONTROL DISPLAY

24EXTERNAL INSPECTION AND CLEANINGCleaning the Air Intake Chamber Screen: • At least twice annually the air intake chamber screen should be

Strona 18

25ELECTRONIC CONTROL DISPLAY REMOVAL / REPLACEMENTImportant: Use only factory authorized replacement parts. If you lack the necessary skills to proper

Strona 19

26POWERED ANODE ROD REMOVAL / REPLACEMENTImportant: Use only factory authorized replacement parts. If you lack the necessary skills to properly perfor

Strona 20

27Installing the Powered Anode Rod:8. Use Teflon® tape or an approved pipe sealant on threads of the new powered anode rod.9. Prior to installing, it

Strona 21

28PRESSURE SWITCH REMOVAL / REPLACEMENTImportant: Use only factory authorized replacement parts. If you lack the necessary skills to properly perform

Strona 22

29TRANSFORMER REMOVAL / REPLACEMENTgCOOLERHOTTERElectronic Control DisplayFigure 40.ON/OFF SWITCHONOFFFigure 41.UNPLUGGEDImportant: Use only factory a

Strona 23 - TROUBLESHOOTING FLOWCHART

3Your safety and the safety of others is extremely important in the servicing of this water heater. Many safety-related messages and instructions have

Strona 24 - Air Intake Chamber

30Installing the New Transformer:10. Insert the wiring connector that goes to the gas control valve/thermostat through the wire protector on the side

Strona 25 - Figure 28

31AIR INTAKE CHAMBER BOX REMOVAL / REPLACEMENTImportant: Use only factory authorized replacement parts. If you lack the necessary skills to properly

Strona 26

3214. Rotate the top of the air intake chamber box from left to right (only a few inches in both directions) while pulling outward at the bottom remov

Strona 27 - Figure 35

33Figure 53.SECURE WITH SCREWS REMOVED EARLIER25. Install the air intake chamber box by rotating the top of the air intake chamber box from left to ri

Strona 28 - Figure 37

34WIRING HARNESS REMOVAL / REPLACEMENTImportant: Use only factory authorized replacement parts. If you lack the necessary skills to properly perform t

Strona 29 - Valve/Thermostat

35Replacing the Wiring Harness:13. Locate the male to female electrical connection with close pin lock on wiring harness (located on the right side of

Strona 30

3625. Install the air intake chamber screen, ensuring that the prongs of the lower portion of the air intake chamber screen are in place in the holdin

Strona 31 - Figure 46

37AIR INTAKE CHAMBER FAN REMOVAL / REPLACEMENTImportant: Use only factory authorized replacement parts. If you lack the necessary skills to properly p

Strona 32 - Figure 52

38Installing the Fan in the Air Intake Chamber Box:11. Plug the electrical connections of the new fan into the wiring harness: Align the electrical c

Strona 33 - Figure 56

39PRESSURE TUBING REMOVAL / REPLACEMENTImportant: Use only factory authorized replacement parts. If you lack the necessary skills to properly perform

Strona 34 - Figure 58

4Fire or Explosion HarzardDo not store or use gasoline or other flammable vapors andliquids in the vicinity of this or any other appliance. Avoid all

Strona 35 - Figure 63

40Installing the Air Intake Chamber Box:11. Check the position the wiring harness wire in the wiring channeling molded down the back center of the ai

Strona 36 - Figure 67

41INNER DOOR/MANIFOLD/BURNER ASSEMBLY REMOVAL / REPLACEMENTImportant: Use only factory authorized replacement parts. If you lack the necessary skills

Strona 37 - Figure 69

42Installation Caution Must Be Taken:10. Prior to installing the new inner door/manifold/burner assembly, look inside the burner chamber to fully unde

Strona 38 - Figure 73

43FLAME SENSE/HOT SURFACE IGNITER REMOVAL / REPLACEMENTImportant: Use only factory authorized replacement parts. If you lack the necessary skills to

Strona 39 - Figure 75

44BURNER REMOVAL / REPLACEMENTImportant: Use only factory authorized replacement parts. If you lack the necessary skills to properly perform the inst

Strona 40 - Figure 80

45Removing Old Burner :11. After noting the position of the condensation drain hole on the top of the burner. Turn the inner door/manifold/burner ass

Strona 41 - TUBE

4616. After confirming no material of any type are between door gasket and combustion chamber shield, align the screws on the inner door with the scr

Strona 42 - Figure 88

47BURNER ORIFICE REMOVAL / REPLACEMENTgCOOLERHOTTERElectronic Control DisplayFigure 102.ON/OFF SWITCHONOFFFigure 103.UNPLUGGEDImportant: Use only fact

Strona 43 - Figure 90

48Removing Old Burner Orifice :11. Burner may be hot, wait until burner has cooled off. After noting the position of the condensation drain hole on t

Strona 44 - BURNER REMOVAL / REPLACEMENT

49Reinstalling The Inner Door/Manifold/Burner Assembly17. Insert the manifold/burner assembly in the burner chamber compartment, making sure that the

Strona 45 - IMPORTANT:

5TABLE OF CONTENTSINTRODUCTION:Service Handbook Introduction ...

Strona 46

50GAS CONTROL VALVE/THERMOSTAT REMOVAL / REPLACEMENTImportant: Use only factory authorized replacement parts. If you lack the necessary skills to pro

Strona 47

5111. Ensuring that the gas supply line is turned off, disconnect the gas piping at the ground joint union, then remove the gas piping from the gas c

Strona 48

5223. Turn on the gas supply to the unit and test the gas supply line and union connections by brushing on an approved noncorrosive leak detection sol

Strona 49

53* To check where threaded portion enters tank, insert cotton swab between jacket opening and fi tting. If cotton is wet, follow draining instructio

Strona 50 - Figure 115

54Draw efficiency is the quantity of hot water available to the consumer before the outlet water temperature decreases 25 degrees F. A 40 gallon wate

Strona 51

55One pound of gas pressure is equal to 27.7 inches water column pressure Inches of Water Column X .036091 = PSI Inches of Water Column

Strona 52 - IF . . . . . . THEN

56ALL TECHNICAL AND WARRANTY QUESTIONS SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED. IF YOU ARE UNSUCCESSFUL, CONTA

Strona 53 - LEAKAGE CHECKPOINTS

6Exhaust Vent toOuside of BuildingUnionUnionWater Shut-Off ValveWater Supply- Cold*Expansion Tank Pressurize to EqualSupply Water Pressure*(Relieve wa

Strona 54 - GENERAL INFORMATION

7COMBUSTION AIR AND VENT SYSTEM REQUIREMENTSTable 1:BTUH InputMinimum Square Feet with 8’ CeilingTypical Room with 8’ Ceiling30,000 188 9 x 2145,000 2

Strona 55

8COMBUSTION AIR AND VENT SYSTEM REQUIREMENTSAll Air from Inside the Building: When additional air is to be provided to the confi ned area from addition

Strona 56

9COMBUSTION AIR AND VENT SYSTEM REQUIREMENTSVent Connectors:1. Type B, Double wall, U.L. Listed Vent Pipe.2. Single wall Vent Pipe.Maintain the manu